Recent contributions
-
Posted #Threads
Design concrete strength up to 100 Mpa?
is there any materials engineer in here? it is possible to design a concrete mix up to 100Mpa cylindrical strength? if possible can you give me...
2 replies -
Replied #Threads
Need advice for roof design.
i suggest also you should model you plan in some structural analysis program, in order you can investigate if that is possible or not. how many...
-
Posted #Threads
THICKNESS OF SOLID SLAB WOULD NOT REQUIRE DOUBLE REINF.?
hi everyone, thus anyone who have an idea what is the thickness of solid slab which is not require a double reinforcement (top and bot).
-
Replied #Threads
Effect of Slab opening in seismic analysis?
im using staad pro v8i, how about if you are using a master slave command represent as you diaphragm, how would it deal with etabs? by...
-
Posted #Threads
Effect of Slab opening in seismic analysis?
In designing seismic analysis or windload: What are the effect of slab opening? and how would be this model in structure in order the diaphragm cannot...
2 replies -
Replied #Threads
What is the difference between expansion and construction joint?
Concrete expands and shrinks with changes in moisture and temperature. The overall tendency is to shrink and this can cause cracking at an early age. Irregular...
-
Replied #Threads
Diaphragm action in building
i just read this one in csi knowledge: #-Link-Snipped-# Rigid diaphragms have infinite in-plane stiffness properties, and therefore they neither exhibit membrane deformation nor...
-
Replied #Threads
Combination of load in raft foundation
just take a look for this one: #-Link-Snipped-# hope it helps
-
Replied #Threads
Diaphragm action in building
in staad rigid here are some explaination regarding your query: 1. Rigid Floor Diaphragm which assumes that the floor is very rigid to experience any in-plane...
-
Replied #Threads
Load distribution between slab and beams & in what proportion?
just download ACI-318 in CHAPTER 13—TWO-WAY SLAB SYSTEMS, it explain how the loads distributed from the slabs to the beam
-
Replied #Threads
STAAD.foundation
hi i like this one "Real strength is not what you have when fighting for only yourself. When you have something special that you want to...
-
Replied #Threads
Combination of load in raft foundation
dear sairaj, can you tell me what design code you are using?
-
Replied #Threads
Dampers
hi, since you were explaining the dampers which is related to seismic analysis. can you explain the what is p-delta analysis? i recently designing a 8-storey...
-
Replied #Threads
New Column over Existing Foundation OR Floating Column?
dear maverick, your proposal location of columns in your drawing is the best solution, just increase the size of your column parallel to the width of...
-
Replied #Threads
How do you design reinforced columns? i need your recommendations.
largest Pu, Mux, Muy. you can check this one on maximum forces by section property if you are using staad pro v8i. but i think it...
-
Posted #Threads
How would staad determine the design loads in column?
dear all, im using staad pro v8i, when i run the analysis sometimes staad choose the less value of my combinations loads.. i used also load...