manoj_2all
Member
- Member since
- Jun 6, 2009
- Last active
- Oct 17, 2012
- Total activities
- 0
Activity feed
Recent contributions
-
#Threads
86d638bb-2cf1-4d98-ae76-3eda561aed5d
Current Transformers – Burden and Classification. Current Transformers occupy a vital part in the measurement and protection scheme of any electric installati...
-
#Threads
595e41be-ebc9-4808-803e-1c222a1d24c1
Yes both Alternator and Generator have same principle of generating power but only in generator we convert the AC voltage supply to...
-
#Threads
9adae6d3-fdf9-45f4-85a1-a9677977c0a1
I have connected all of them to one neutral bus and connected that bus to ground via NGR (Neutral Grounding Resistor) it...
-
#Threads
2fbfae10-74c2-4ca2-af10-68f19c0eca72
dileep kGenerally,in brief my lecturer told that SCADA is computer based process of supervisory control and data acquisition and when the fault...
-
#Threads
0d738df0-a79c-4db7-91a2-7a481261b286
As there is no Back EMF existing on the motor side due to this the motor consumes high starting current as it...
-
#Threads
9e1b0daf-ad43-471e-8b64-69f062060edb
Yes you are right, may be there is fault in the motor side not with the source side......
-
#Threads
436beb0b-6f82-46a6-9052-30479b8c5c3b
Neutral is the point at which all the three phase’s current meets and the algebraic sum of current becomes zero in case...
-
#Threads
b4e08f39-3972-4e27-99e7-8e48fbdea9cf
The burden of a current transformer is indicated in its nameplate. The burden is rated in VA. such as 15 VA or...
-
#Threads
274076c8-bc94-4ff3-bca4-430604aca518
Check for Slip Ring Motors; Demag: #-Link-Snipped-#
-
#Threads
2ad0a325-d06b-49c2-906f-c00dff0debcd
Yes it works like a Switch; ON (Active) and OFF (De-active) state but the equipments in remote places.
-
#Threads
265c2046-fc2f-48b4-a248-60db90631981
SCADA: SCADA refers to a system that enables an electricity utility to remotely monitor, coordinate, control and operate transmission and distribution. Componen...
-
#Threads
25fe8791-a22c-4b85-9926-5b4d0e703402
Re: wat is the different b/w wi-fi and wi-max Transformer must not be connected to a DC Source because if the primary...
-
#Threads
37674188-0e91-418a-a1dc-af6b86916af8
1. Single phase voltage is compare then three phase voltage is very low for ex- 1 phase 240v < 3 phase 440v....
-
#Threads
44234aeb-8345-490b-965d-c76ed879f48d
This is an Project for Shop Doors using PLC Programme Specifications: • The entrance consists of two sliding doors. • The doors...
-
#Threads
Electrical Basics - Question and Answers