Sagar Jiyani
Member
- Member since
- Jan 28, 2019
- Last active
- Mar 28, 2019
- Total activities
- 0
Activity feed
Recent contributions
-
#Threads
9fcce8d8-5ba3-446f-9ef0-e164cbf2ff04
Ok sir..thnks..
-
#Threads
1c1597b3-27f5-4146-a560-f130012f21d3
SIR CAN YOU GIVE ME THE T-R SET DETAIL FOR 2 TPH BOILER ESP?
-
#Threads
68633890-3ea2-4290-8d5e-ff9e71104d8a
lime stone powde or lime slurry is not better efficient more than naoh. lime stone or slurry has efficiency around 80-90% where...
-
#Threads
883f3c65-20d8-451a-a40d-eca68bfde2c2
as u mentioned erlier that only water spray also can remove sox from flue gases. is that possible? if es then which...
-
#Threads
Electro static pracipitator required power calculation?
i m from engineering firm.in india there is above 7 tph boiler used ESP for dust remove from flue gas.if i want...
-
#Threads
9a386e89-a63e-46a7-9954-fd6673584f58
Ok sir..i get it ..in short i have to require 75 kg/hr naoh for complete sox remove.
-
#Threads
7fd0edc3-1bc6-4cfa-a562-cd923cfbae0e
Ok.sir..i get your mean. But if we get ph value 12 ph then reaction occurs with sox in flue gas and according...
-
#Threads
956cb061-8a51-4ae0-b2cd-899a0330e065
thanks for your response sir,but our procedure is like we are adding naoh into 12000 ltr water and maintaining its ph value...
-
#Threads
055844f3-3a32-4fcb-9ab0-4647a4e3d4ec
sir,if we are using naoh with water solution then there is possibility to less naoh absorption? because if there is 75 kg/hr...
-
#Threads
6fc431c7-7195-4781-80fe-fa40f8c3418d
But we can get 12 ph value of water and naoh solutions so per ltr of water 0.4 gm naoh required.so if...
-
#Threads
922f6c33-c6cb-4206-b468-f7027a3d48f1
As a practically i need to give a data to our client that how much naoh required in a day or in...
-
#Threads
73d97bb0-2383-46f0-a205-ef581b6feb65
As a practically i need to give a data to our client that how much naoh required in a day or in...
-
#Threads
Naoh Scrubbing system required amount of naoh
for naoh scrubbing system how much naoh required for 22620 kg/hr flue gas and 0.13% so2 by volume.?Can we get a calculate?
-
#Threads
8bdd7160-5ddc-438a-b3f2-aee3706f18e3
Respected #-Link-Snipped-# sir,As per your suggestion using hydrogen peroxide is the best solution.but client demanding caustic (naoh or other) based scrubber.s...
-
#Threads
0fb44afd-e4cf-442c-9db9-a3491d070042
Respected #-Link-Snipped-# sir,As per your suggestion using hydrogen peroxide is the best solution.but client demanding caustic (naoh or other) based scrubber.s...
-
#Threads
SOx and NOx reduction of boiler flue gas
hello friend,i am from SWASTIK ENGINEERING. actually , i wanted to know thathow can i controll SOx and NOx from boiler flue...
-
#Threads
new startup with some best ideas
i am self interpreter. actually i have just started up an engineering work shop in gujarat. its SWASTIK ENGINEERING -PALASANA. THERE IS...